CVE-2026-111218
Netgate pfSense CE 2.7.0 through 2.9.0 contains an OS command injection vulnerability that allows authenticated users with Traffic Shaper Limiters privileges to execute root…
Archived. This CVE has left SubZer0's live 30-day window. Signals below are as of 2026-11-14; check the references for anything newer.
- Severity: High
- CVSS 8.6
- EPSS 8.65%
- Public exploit
- P2 · This week
Why P2: this week.
Description
Netgate pfSense CE 2.7.0 through 2.9.0 contains an OS command injection vulnerability that allows authenticated users with Traffic Shaper Limiters privileges to execute root commands by tampering with the limiter number field. Attackers can submit a malicious hidden 'number' value when editing a limiter, then delete it so delete_queue() passes the unquoted value to dnctl via /bin/sh as root.
Affected products
- pfsense >= 2.7.0, <= 2.9.0
Weakness
CVSS vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
References
- NVD record NVD
- CVE Program record CVE Program
- Reference NVD
- Reference NVD
- Reference NVD
- Reference NVD
- Reference NVD
- Reference NVD
- GitHub security advisory GitHub